A.N.B. Electronics Co., Ltd. · Industrial power solutions in Thailand
Product resource · Engineering reference

MEAN WELL LRS-75-36

36V DC · 2.1A · 75.6W enclosed AC/DC power supply

Single-output enclosed switching supply in the MEAN WELL LRS-75 series. Use the verified ratings below to assess load compatibility and compare the available output-voltage variants.

Before specifying, verify the latest model ratings, datasheet revision, applicable approvals, availability, and installation derating requirements using the manufacturer datasheet linked below.

MEAN WELL LRS-75 power supply

Specifications that matter

75.6W
Rated output power

Model electrical ratings

Output voltage36V
Rated output current2.1A
Rated output power75.6W
Typical efficiency91.5%
Output adjustment32.4 ~ 39.6V
Ripple & noise (maximum)200mVp-p

Engineering considerations

Verify AC input conditions, load profile, installation orientation, wiring, ventilation and ambient-temperature derating against the manufacturer's datasheet.

Nominal series power is not necessarily the rated power of every output-voltage variant. This page uses the model-specific rating.

Source: Manufacturer Datasheet.

Will LRS-75-36 support your load?

Estimate steady-state load utilization at the model's nominal DC output. This is a planning calculation, not a substitute for temperature derating, startup-current or transient-load analysis.

Compare LRS-75 models

Voltage variants within this series differ in output current, rated power and efficiency. Select the model matching your load voltage first.

ModelDC outputRated currentRated powerEfficiency (typ.)
LRS-75-55V14A70W86.5%
LRS-75-1212V6A72W89%
LRS-75-1515V5A75W89%
LRS-75-2424V3.2A76.8W90%
LRS-75-3636V2.1A75.6W91.5%
LRS-75-4848V1.6A76.8W91.5%

Explore the complete LRS family →

Installation considerations

Thermal design

Apply the manufacturer's temperature and input-voltage derating curves; ensure adequate free-air convection and clearance.

Load characteristics

Check startup surges, motor loads, capacitive loads and transient peaks in addition to steady-state current.

Electrical safety

Use qualified installation practices, correct protective earth and appropriate input/output wiring. Verify the latest approvals for your application.

Manufacturer resources & quotation

Manufacturer values reflect the supplied datasheet revision. ANB can help verify the exact part number and current availability.